Localizar produto:
     Logotipo_Fluke.GIF (498 bytes)   
FLUKE - 320 SÉRIES CLAMP METERS
 
Now everyone on your crew can have a Fluke Clamp Meter. Two new smaller sized models available offering accurate low current measurements, continuity test function and Fluke reliability. Choose the model that best fits the way you work.


Technical Specifications
AC Current

Range
321: 0-400.0 A
322: 0 - 40.00 A, 40.0 - 400.0 A
Accuracy
321: 1.8% ± 5 counts (50 - 60 Hz) 3.0% ± 5 counts (60 Hz - 400 Hz)
322: 1.8% ± 5 counts (50 - 60 Hz) 3.0% ± 5 counts (60 Hz - 400 Hz)
AC Response
321: Averaging
322: Averaging
AC Volts

Range
321: 0 - 400.0 V, 400 - 600 V
322: 0 - 400.0 V, 400 - 600 V
Accuracy
321: 1.2% + 5 counts (50 - 400 Hz)
322: 1.2% + 5 counts (50 - 400 Hz)
AC Response
321: Averaging
322: Averaging
DC Volts

Range
321: Not Applicable
322: 0 - 400.0 V, 400 - 600 V
Accuracy
321: Not Applicable
322: 1% + 5 counts
Resistance

Range
321: 0-400.0 Ohms
322: 0-400.0 Ohms
Accuracy
321: 1% ± 5 counts
322: 1% ± 5 counts
Continuity
321: < 30 Ohms
322: < 30 Ohms


General Specifications
Min/Max No
Backlight No
Operating Temperature -14 °F to 122 °F (-10 °C to 50 ° C)
Battery Life (2) AAA carbon zinc approximately 100 hours continuous, automatic low battery indicator.
Safety Rating IEC 1010-2-031, 600 V CAT III
Warranty Two years
Temperature De-rating < 18 °C, > 28 °,C add 0.1 x specified accuracy / °C
Storage Temperature -22 °F to 140 °F (-30 °C to 60 °C)
Display Hold Yes
Size Height 7.5" (19.05 cm)
Width 2.5" (6.35 cm)
Depth 1.4" (3.50 cm)
Jaw Opening 1" (2.54 cm)
Weight   8 oz. (224 g)
 
     Link_Volta.GIF (1048 bytes)
 
MULTITEC - Instrumentos de Medição Ltda.
Rua Pedro Ernesto, 70-Lj - Saúde - Rio de Janeiro - RJ CEP:. 20220-350
TEL: (0XX21) 2233-3283 / 2516-2153 :: FAX: (0XX21) 2233-3847