| MULTIMETERTM Fluke 70 SÉRIE III |
|
Voltage DC |
Maximum Voltage: Fluke 73: 600V / Fluke 77: 1000V Basic Accuracy: 0.3%
Maximum Resolution: 0.1 mV |
|
Voltage AC |
Maximum Voltage: Fluke 73: 600V / Fluke 77: 1000V Basic Accuracy: 2%
Maximum Resolution: 1 mV |
|
Current DC |
Maximum Current: 10 A Maximum Resolution: 0.01 mABasic Accuracy: 1.5% |
|
Current AC |
Maximum Current: 10 A Maximum Resolution: 0.01 mA Basic Accuracy: 2.5% |
|
Resistance |
Max Resistance: 32 MW Basic Accuracy: 0.5% Maximum Resolution: 0.1 W |
|
Environmental Specifications |
|
Operating Temperature |
0°C to +50°C |
|
Storage Temperature |
-40°C to +60°C |
|
Humidity (Without Condensation) |
0% - 90% (0°C - 35°C) / 0% - 70% (35°C - 50°C) |
|
Operating Altitude |
2000 m |
|
Overvoltage category |
Fluke 73 III: EN 61010-1 to 600 V CAT II
Fluke 77 III: EN 61010-1 to 600 V CAT III/1000V CAT II |
| Agency Approvals |
UL, CSA, TÜV listed |
|
Mechanical & General Specifications |
|
Size |
Fluke 73 III: 166 x 75 x 28 mm
Fluke 77 III: 190 x 89 37 mm |
|
Weight |
Fluke 73 III: 340 g / Fluke 77 III: 365 g |
|
Warranty |
Lifetime |
|
Battery life |
Alkaline: ~2000 hours typical |
|
Shock & Vibration |
Per MIL-T-PRF 28800F Class III |
|
 |
| MULTITEC - Instrumentos de Medição Ltda. |
Rua Pedro Ernesto, 70-Lj - Saúde - Rio de Janeiro - RJ CEP:. 20220-350